Filter Results By:
Products
Applications
Manufacturers
Current Transformers
transfers accurately proportional levels of current to multiple circuits.
-
product
Advanced Primary Injection Test Set
PI-2500
The PI-2500 is a versatile and technologically advanced primary injection tester capable of testing circuit breakers up to 2000 amperes frame size. It incorporates a low-impedance output transformer with dual secondaries to provide optimal impedance matching to a wide range of breaker sizes. High-capacity internal fan cooling allows maximum utilization of the output transformer and faster recovery after overload conditions. It is housed in a rugged aluminum frame enclosure with removable sides allowing easy access to all internal components to facilitate ease of service and maintenance. The output of the test set is controlled by means of a proven SCR controller. This provides precise initial phase angle control to reduce DC offset for inductive loads and more consistent pulse currents.
-
product
904 Benchtop Six Phase 30A
Weshine Electric Manufacturing Co., Ltd
1. The instrument has standard six phase voltage and six phase current output. It can test not only traditional relays andprotection devices, but also modern micro-computer protection devices, especially for transformer differential protection and standby automatic switching device. The test is more convenient and perfect.2. can be connected to laptop (optional) to run.Laptops and industrial computers use the same set of software, so there is no need to relearn the operation method.
-
product
IP67 waterproof outdoor Split core ct
LZCK-55 200/5A 0.5S
Beijing GFUVE Electronics Co.,Ltd.
Outdoor waterproof Split Core CTs. Waterproof outdoor split core current transformer 55mm. Outdoor Split-core CTs are designed to meet the growing demand for outdoor installation. The working temperature and humidity is high. Parameters will be measured and compared without power supply cut-off on account of the split core, so it's popular in the energy management system and power factor correction. It can be used along with many kinds of instruments and devices.
-
product
Turns Ratio Meter
Model TRM200
Turns Ratio Meter Model TRM200 is widely used in transformer industry in manufacturing and repairing service. It directly display the ratio of LT turns & HT turns. It is capable to measure turns ratio till 1:1200. Turns ratio meter is designed to be a rugged and reliable. It is equipped with stable 250mA source. The design is based upon in-house invented & patented technology. TRM200 has also option for 1amp current source on demand.
-
product
FTL Test Block
FTL testblock with dust cover and current disconnect pinThe FTL is a test block for interfacing substation devices (protection relays, fault recorders, revenue meters, ... ) to the voltage and current transformers and to other equipment on the system side of a power grid. The FTL test block uses disconnect pins to isolate the substation devices from the system side equipment. Once isolated, secondary injection can be performed using banana jacks on the front side of the test block.
-
product
903 Benchtop Three Phase 40A
Weshine Electric Manufacturing Co., Ltd
1. The instrument has standard four phase voltage and three-phase current output. It can test not only various traditional relays and protection devices, but also various modern microcomputer protections, especially for transformer differential protection and standby automatic switching device. The test is more convenient and perfect.2. Classic Windows XP operation interface, friendly man-machine interface, easy and fast operation; high performance embedded industrial control computer and 8.4 inch resolution 800 × 600 TFT true color display screen, can provide rich and intuitive information, including the current working state of the equipment and various help information.
-
product
Adjustable Isolating Transformers
PeakTech Prüf- und Messtechnik GmbH
The PeakTech 2235 is a 2 in 1 laboratory isolating transformer with integrated DC power supply, which was designed with the aspect of high safety requirements for use in research, science and repair. The device has a dual adjustable DC, AC output, which can also be used for constant voltage or current and offers high stability and performance. The output voltage or the output current can be read exactly on two separate 3-digit LED displays and the fixed output supplies a voltage of 5 V. The device is protected against damage by overload and short circuit by reliable overvoltage protection and can be placed in a 19 ”rack installed or used as a table device (“stand-alone”).
-
product
High Voltage Power Supplies
The mains voltage (230V / 3 x 400V) is transformed, rectified and filtered by the HN series. The direct current output voltage is tuned by a variable transformer or regulated by a thyristor controller. With the HS and HV series the rectified mains voltage is supplied to a frequency converter, which produces a mid-frequency square wave voltage. This transformed, rectified and filtered alternating current produces the desired voltage as output, which is regulated by means of frequency variation or pulse width modulation. The equipment in the HV series supply, in addition to the high voltage output, up to 3 auxiliary outputs which can be used to supply e.g. heating, grid voltage or surge voltage.
-
product
NI-9247, 50 kS/s/ch, 50 Arms, 147 Apk, 24-Bit, 3-Channel C Series Current Input Module
783589-01
50 kS/s/ch, 50 Arms, 147 Apk, 24-Bit, 3-Channel C Series Current Input Module - The NI‑9247 is designed to support direct ring lug connectivity to the three-phase high-current measurements of 1 A and 5 A current transformers (CTs). It is optimized for power, energy, and industrial applications. The safety features, certifications, input ranges, overvoltage ranges, and connectivity are well suited for applications such as power quality monitoring and metering, utility pole-mounted smart switches, utility pole-mounted smart grid reclosers, substation merging units, industrial machine measurements, health monitoring, predictive maintenance and prognostics, and phasor measurement units (PMUs).
-
product
NI-9246, 50 kS/s/ch, 20 Arms, 30 Apk, 24-Bit, 3-Channel C Series Current Input Module
783920-01
50 kS/s/ch, 20 Arms, 30 Apk, 24-Bit, 3-Channel C Series Current Input Module - The NI‑9246 is designed to support direct ring lug connectivity to the three-phase high-current measurements of 1 A and 5 A current transformers (CTs). It is optimized for power, energy, and industrial applications. The safety features, certifications, input ranges, overvoltage ranges, and connectivity are well suited for applications such as power quality monitoring and metering, utility pole-mounted smart switches, utility pole-mounted smart grid reclosers, substation merging units, industrial machine measurements, health monitoring, predictive maintenance and prognostics, and phasor measurement units (PMUs).
-
product
Programmable Micro-Ohmmeter
4300C
The 4300C is the perfect instrument for tackling ultra-low resistance testing requirements associated with motors, transformers, fuses, connectors, breakers, bonding/weld resistance, and many other applications. The 4300C Digital Micro-Ohmmeter measures a variety of low-resistance devices ranging in value from 100nΩ to 20kΩ. The flexible measurement format of the 4300C provides six ranges of user selectable test current (from 0.1mA to 10A) and three voltage sensitivity settings (20mV, 200mV, and 2V).
-
product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.
-
product
DC Bias Current Power Supply
TH1775
Shenzhen Chuangxin Instruments Co., Ltd.
TH1775 is a DC Bias Current Source (or DC Magnetization Current Source) used for inductance measurement of inductors and transformer windings with DC bias current. Except for constant current output, low additional error and wide frequency response range are important for bias current inductance measurement. High frequency LCR meter could be used, when the frequency response range is wide enough. MPU controlled auto current balance technology is adopted to realize AC+DC current overlap and constant current output from 0 to ±20A. Two TH1775 can be paralleled to supply a maximum current up to 40A.TH1775 permits high frequency measurement up to 1 MHz and can be directly controlled by TH2816A, TH2817A, TH2818 and TH2819. TH1773/TH1775 with its low additional error, wide frequency response range and sweep output function is widely used in DC biased inductance measurement. TH1775 also provides a perfect solution for magnetic material analysis.
-
product
Ground-Fault Location Products for Ungrounded Systems
When combined with Bender's ground-fault detectors and current transformers, EDS series modules provide fast, automatic ground-fault location in ungrounded systems. Fault location takes place while the system remains online without the need to open branch circuit breakers or disconnect equipment. Bender's fault location system works on both AC and DC systems, as well as systems with variable frequency drives. A standalone, portable fault location system is also available.
-
product
5kV Insulation Resistance Tester
KV3122
KV Hipot Power Test Equipment Co.,Ltd
KV3122 Insulation Resistance Tester is suitable for measuring the resistance of various insulating materials and the insulation resistance of transformers, motors, cables and electrical equipment. Digital insulation resistance meter is composed of medium and large scale integrated circuits, including high-precision micro current measurement system, digital boost system and automatic discharge circuit.
-
product
Intelligent Digital Power Meter
9800N
Shenzhen Chuangxin Instruments Co., Ltd.
RK9800N series intelligent digital power meter can simultaneously measure the single and three phase electrical equipment’s voltage, current, power, power factor, frequency, and harmonic parameters etc. It’s widely used in motor, household appliances, electric tools, water pumps, transformers, power supply, lighting, electricity and other fields.
-
product
Power Quality Analyzer
Power quality analyzer is a product carefully developed by our company and specially designed for field test of three phases, multi-functional and intelligent, man-machine operation and concise and comprehensive test instrument. It is easy to use, large LCD screen display, high resolution, interface in both Chinese and English, shock-proof shell structure and so on. Can simultaneously measure the 4-channel current (ABC three phase and neutral wire current), 4-channel voltage (ABC three-phase voltage and neutral line voltage to ground), the peak value of current voltage, maximum/minimum value over a period, three-phase imbalance factor, short-time voltage flicker, transformer K factor, active power, reactive power, apparent power, power factor and displacement power factor, active power, reactive power, apparent power, total harmonic distortion and harmonic, etc; Display real-time waveform, harmonic ratio bar charts of current voltage; Dynamically capture instantaneous change of voltage current, monitoring starting current, monitoring the power parameters and generate the alarm list, generate the trend chart for a long time record test data.
-
product
Oil Immersed Test Transformer
SG-YD
Wuhan Sangao Electrical Test Installations Limit Co.
AC and DC test oil immersed transformer.Traditional oil immersed test transformer is used to do power frequency withstand voltage and DC current withstand voltage test for variety kinds of high voltage electric device, insulating material.YD series oil transformer, also known as test booster, which test insulation strength under specified voltage for various electric products, components, insulation materials. It can test products insulation level, find insulation defect and judge overvoltage ability. It is widely used in power station, power supply and distribution system and research institute.
-
product
Surge Tester (Impulse Winding Tester)
SS6815 / SS6815F
Surge testers (impulse winding tester) is used for testing and check the insulation grade of turns between turns, insulation grade of layers between layers, insulation grade of windings between turns. It is used widely for transformer, current sensor, voltage sensor, relay, contactor, inductor, motor, generator, valve coil, voice coil, etc.
-
product
Transformer Winding Resistance Meters
RMO TT Series
The Tap Changer Analyzer & Winding Ohmmeter of the RMO-TT series is designed for winding resistance measurement of inductive objects, and for a tap changer analysis. The RMO-TT series is based on the state of the art technology, using the most advanced switch mode technology available today. The RMO-TT instruments are accurate (0,1%), powerful (up to 100 A) and still portable. The Instruments generate a true DC ripple free current with automatically regulated measurement and discharging circuit. RMO-TT instruments can perform a simple, quick and reliable transformer on-load tap changer condition assessment. This series of instruments enable measurements of a winding resistance in every tap position, current ripple values (percentage of a current drop during a tap change) and transition times during the tap changes. Problems with a connection, contacts, and selector/diverter switch operation (tap change with interruption) can be detected with these measurements.
-
product
Fully Automatic Transformer Winding Resistance Tester
Measure DC resistance of transformers windings etc. Introduction: The NMC ''TDR'' is a high precision, new generation, light weight large output current and micro-processor controlled tester. This replaces old DC wheat stone bridge and double arm bridge for measurement of DC resistance. ''TDR'' adopts new advanced test current power supply technology, four terminal measurement, digital display of resistance value and test current. ''TDR'' is powered by 220V AC mains single phase supply. The measurements are accurate as the test current is highly stable. High automation is achieved with automatic discharge warning.Principle: The constant current generated is fed to the resistance under test through the current terminals and the voltage drop across the resistance under test is measured and displayed in ohms. A true four terminal measurement is used to eliminate the need for lead resistance compensation.
-
product
Turns Ratio Testers
TRT Advanced Series
TRT Advanced series is the newest DV Power solution for transformer turns ratio measurement. Besides its main application, each turns ratio tester from this series also measures transformer excitation current and phase shift. Furthermore, all models perform automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. They have a built-in true three-phase power source. For that reason, they can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 500 V AC, depending on the model. With the highest test voltage 500 V AC, TRT500 provides the most accurate turns ratio testing of power transformers used in power generation and transmission. The output test voltage of TRT500 can be boosted to 5 kV AC using the external CVT20 extension transformer. This application is specially designed for testing turns ratio of capacitive voltage transformers. The other three models, TRT400, TRT250, and TRT100 can output up to 400 V, 250 V, and 170 V respectively. The low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT500 is equipped with a large 10.1” graphical touch screen display. Other models, (TRT400, TRT250, TRT100) have 7” graphical touch screen display. Besides making the interface much more user-friendly compared to older turns ratio testers, it also brings certain options that were previously available only with DV-Win software. The most important are test templates and automatic test mode. Users can simply create test templates, store them in the instrument’s memory, and load when in the field with just a few clicks.This turns ratio test set, as well as all other DV Power turns ratio testers, has a built-in tap changer control unit. It enables remote control of an on-load tap changer (OLTC) directly from the instrument. In order to make the most out of this feature, the instrument can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time. Automatic test mode minimizes human errors, which makes the measurement more reliable.
-
product
DC Power Supply
PW-3063R
*Use Toroidal Transformer. Low EMI & High EMS.*Triple output, 0-32V/0-6A X2 and 5V/3A .Max. 400Watts*Tracking operation. Max. output 64V/6A on tracking series or 32V/12A on tracking parallel.*4 display, Green LED shows Voltage and Red LRD shows Current. Easy to read.*Compact design. G.W. 9Kgs only. Easy to handle.*The resolution of PW-3063R as high as 0.1v and 0.01A.*Very low Ripple & Noise, less than 0.4mVrms. Very suit for precise measurement.
-
product
AC Electronic Load
The electronic AC loads cover a wide variety of different voltage, current and power ranges. All the AC loads are programmed with 11 different sine, square and DC waves. With 5 crest factor variations of each, a total of 55 waveforms are available. An external input is also provided to enable the user to amplify signals from a waveform generator.AC Loads allow real world operating conditions to be simulated. Typical applications include circuit breaker, transformer & UPS output testing along with general laboratory and research work.
-
product
High-Voltage Test Device
PGK 150 HB
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PGK HB. There are hardly any other longer-lasting, more robust and cost-effective testing devices than the two-piece high-voltage test devices from the PGK HB series. They generate continuous adjustable test voltages with mains frequency or optionally DC with positive or negative polarity. The display instruments for current and voltage, the safety control unit and the regulating transformer for the voltage are integrated in the operating unit.* Operation as DC or AC testing device* Polarity of the DC voltage can easily be reversed* Robust and durable
-
product
High-Voltage Test Device
PGK 70/2.5 HB
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PGK HB. There are hardly any other longer-lasting, more robust and cost-effective testing devices than the two-piece high-voltage test devices from the PGK HB series. They generate continuous adjustable test voltages with mains frequency or optionally DC with positive or negative polarity. The display instruments for current and voltage, the safety control unit and the regulating transformer for the voltage are integrated in the operating unit.* Operation as DC or Ac testing device* Polarity of the DC voltage can be easily be reserved* Robust and durable
-
product
High-Voltage Test Device
PGK 110 / 5 HB
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PGK HB. There are hardly any other longer-lasting, more robust and cost-effective testing devices than the two-piece high-voltage test devices from the PGK HB series. They generate continuous adjustable test voltages with mains frequency or optionally DC with positive or negative polarity. The display instruments for current and voltage, the safety control unit and the regulating transformer for the voltage are integrated in the operating unit.* Testing as DC or Dc testing device* Polarity of the DC voltage can easily be reversed* Robust and durable
-
product
Front End Protector
AS-RXFEP RX
The AS-RXFEP Receiver protector limits input RF signal threshold from 1 to 150MHz to less than 0.3 Vrms to protect a receiver front end from damage due to nearby transmitted signals. The receiver still actsnormally and measured signal strength is not affected.The circuit uses a multi-stage design of transformer saturation coupling and current limiters. It also incorporates a low voltage GDT to protect from lightning events. These are for receiving only - you cannot transmit through them without damaging the unit.
-
product
Static Frequency Converter Systems with Built-in Isolation System
FC3X Series
- VFI independent output as per IEC62040- User friendly controls and indications- Compact design with inbuilt transformer- Rugged and field proven for Industrial and Defence application- Ultra light weight- Higher efficiency of operation means significantly lower running costs- State of the art IGBT based PWM technology, to increase crest factor tolerance & dynamic stability- Continuously delivers full output power at ambient as high as 45ºC- Can feed upto 400% rated current for half cycle- Very high MTBF
-
product
Transformer Winding Resistance Tester
KRI 9310
KRI 9310 adopt Kelvin four-wire testing method, which effectively eliminates the influence of the resistance of the test line on the test results. It can be able to increases the current to 10A by which can test extremely low resistance to 0.01 Ω(such as amorphous alloy, Copper-nickel, nickel-chromium-iron, iron-chromium-aluminum etc). For the tested objects with high resistance value (CT/PT), the instrument can extend the range to 20 kΩ,so the wide resistance test range enables KRI9310 can cover 80% of the power transformer products on the market and switchgear bus-bar cable etc. The power of the tester use the built-in rechargeable lithium battery that can test hundreds of transformers by one time charging.